Series 10 Analog Electronic Controls
Single or double output with analog and digital display outputs

Select analog or digital display output
Relay or solid state outputs
RTD, Thermistor or Thermocouple inputs

Single or double output capability
on/off or time proportioning
Compact and economical

Series 10 offers state-of-the-art technology to provide single or dual stage control (two independent outputs). Ultra reliable on/off or time proportioning for heating or cooling applications to drive contactors, solid-state relays or triacs. Two channel heating/cooling to maintain tight process temperatures. Ideal for ovens, mold controllers, environmental chambers. Use one channel for boost heat and the other for maintaining set point, for example in large power drying systems.

These versatile controllers will accept thermistors, RTD's or thermocouples types J and K. Choose temperatures between -100 and +1000 degrees C. In addition, an auxiliary output is provided for add-on temperature indication - analog (0-1 mA DC), digital (12 VDC or 5VDC) and deviation meter (5 VDC).

A low cost effective alternative to DIN packaged controllers, Series 10 comes complete with local or remote set potentiometers and with handsome 2.25in skirted knob and scale calibrated in degrees C and F.

Series 10 provides six different output modes

Function

Description

Code

Heating  

Driving contactors, solid state relays or triacs to regulate a heating process  

A

Cooling  

Driving solenoids to regulate a refrigeration process  

B

Heating/cooling (tracking)  

Two independent relay or triac outputs for driving contactors (solid state relay or triacs) and simultaneously solenoids to maintain tight process temperatures. Ideally suited for film processing, one, mold controller and environmental chamber applications  

C

Two stage heating

Two independent tracking and non-tracking outputs similar to above but suited for two stage heating systems, typically a high powered heater for raising process temperature quickly and a low power heater for maintaining set point temperature (for example, large power drying systems)  

D

Heating/Hi Alarm

Two non-tracking outputs for regulating a heating process and providing a switching signal to activate a high temperature alarm

E

Heating/ Lo Alarm

Similar to above, but designed to activate an alarm below set-point

F

On-off or time proportioning control

On-off controls are either full on or full off. The controlled element is switched at precisely the selected set point. The factory set hysteresis is typically ±0.25°C but controllers can be supplied with wider or narrower dead bands.

The control recognizes the deviation from set point and proportions corrective action as a function of the temperature deviation. The action takes place when the temperature falls within a preset temperature range around the set point known as the proportioning band. The controller progressively reduces or increases the ratio of time-on to time-off until temperature equilibrium is reached. Power is switched on and off with full line cycles to minimize radio frequency interference.

Output ratings

For inductive or alarm applications, relay outputs are suggested. For resistive heating applications. triac outputs are suggested. The triac output can also drive and externally mounted triac when load requirements exceed the controller output rating. See Quantem P/N 212-70038 25A Triac “Quick-Pak”.  


SPECIFICATIONS

SERIES 10

Temperature ranges available  

Thermistor: -20/100C 2K ohm, 25/175C 30K ohm, 50/250C 100K ohm, 100/325C 500K ohm
RTD: -100/100C 100 ohm, 0/250C 100 ohm, 0/400C 100 ohm, 0/600C 100 ohm
Thermocouple: 0/250C, J, 0/500C, J, 0/1000C, K
 

Stability:  

0.05 deg C with 1 deg C ambient change or 0.01% of span with 1% line voltage change  

Accuracy:  

0.25% FS

Control type:

On/off or time proportioning (one or two channels)

Control output:

SPDT relay (3A or 10A), triac (2A, 10A or 15A), 30mA external SSR, dual relay (3A), dual triac (2A)  

Output type:   

(Single output) heating, cooling; (Dual output) heat/cool, heat/heat, heat/high limit, heat/low limit, high/low alarm  

Set potentiometer:

Fixed, local or remote  

Sensor:

Thermistor, RTD or thermocouple (J/K)  

Operating ambient:   

0-55 deg C  

Power:

120/240VAC (field selectable)  

Auxiliary output signal

None, analog (0-1 mA DC), digital LCD (12VDC), digital LED/LCD (5VDC), deviation (1 mA DC)  

Panel cut-out:

Sub-panel mount, potentiometer shaft 3/8in diameter  

Included as standard: 

220-20001 Potentiometer, 221-10027 Knob/scale 2.25in  

Series 10 can be provided optionally with an output for a digital temperature indicator. For more details of our indicators see Model TR-25.

Standard Series 10 which are available
See Technical Information – Analog part numbers for specifying other versions of Series 10  

Model #  

Power  

Sensor  

Range

Control

Output  

Set pot

10-A04-10-LZ006  

240V  

RTD

85/135F  

On/off

10A relay  

Local

10-A04-10-RZ055

240V

RTD

85/135F  

On/off

10A relay  

Remote  

10-A04-20-RZ027  

120/240V

RTD

No dial/range

Proportional  

10A relay  

Remote  

10-A04-20-RZ033  

120/240V  

RTD

200/600F  

Proportional  

30mA

Remote  

10-A06-24-RZ037  

120V  

RTD

0/1000C

Proportional  

10A relay  

Remote  

10-A08-10-RZ012  

120/240V

RTD

-100/100C  

On/off

10A relay  

Remote  

10-C10-60-R502  

120/

240V

RTD

-100/100C  

Proportional  

3A relay
15A triac

Remote  

Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


Quantem Corporation
1457 Lower Ferry Road , Trenton , NJ 08618 Telephone 609-883-9191, Fax 609-883-9879. www.quantemcorp.com

Bulletin # Series10/8/2002